Switched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.

Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

APC AP7900B. PDU tipos: Conmutado, Capacidad del rack: 1U, Montaje: Horizontal. Cantidad de salidas AC: 8 salidas AC, Tipo de salida AC: NEMA 5–15P, Conector: NEMA 5–15P. Longitud de cable: 3,65 m, Certificación: UL/cUL, PSE, FCC Part 15 Class A, IC ES-003 Class A, VCCI Class A. Voltaje nominal de entrada: 100 - 120 V, Máxima corriente: 15 A, Frecuencia de entrada AC: 50 - 60 Hz. Dimensiones (Ancho x Profundidad x Altura): 444,5 x 108 x 44,5 mm, Peso: 2,26 kg

PDU tipos Conmutado
Capacidad del rack 1U
Montaje Horizontal
Color del producto Negro
Cantidad de salidas AC 8 salidas AC
Tipo de salida AC NEMA 5–15P
Conector NEMA 5–15P
Indicadores LED Si
Longitud de cable 3,65 m
Certificación UL/cUL, PSE, FCC Part 15 Class A, IC ES-003 Class A, VCCI Class A
Voltaje nominal de entrada 100 - 120 V
Máxima corriente 15 A
Frecuencia de entrada AC 50 - 60 Hz
Voltaje nominal de salida 120 V
Corriente total máxima por fase 15 A
Dimensiones (Ancho x Profundidad x Altura) 444,5 x 108 x 44,5 mm
Peso 2,26 kg
Peso del paquete 3,4 kg
Intervalo de temperatura operativa -5 - 45 °C
Intervalo de temperatura de almacenaje -25 - 65 °C
Intervalo de humedad relativa para funcionamiento 5 - 95%
Intervalo de humedad relativa durante almacenaje 5 - 95%
Altitud de funcionamiento 0 - 3000 m
Altitud no operativa 0 - 15000 m
Rango de temperatura de funcionamiento 23 - 113 °F
Certificados de sostenibilidad RoHS
APC
AP7900B

Ficha técnica

Cantidad de salidas CA
8
Corriente máxima
15 A
Tamaño de rack
1U
Tipo de PDU
Conmutado
Tipo de salida de CA
NEMA 5-15P
Voltaje nominal de entrada
100 - 120 V

Referencias Específicas

upc
731304331568
ean13
0731304331568
Nº Pieza fabricante (NPM)
AP7900B